276°
Posted 20 hours ago

Replacement Synchronous Motor for motorised valves ACL Honeywell Landis Gye Satchwell Sopec Tower DIY Replacement 2-Port 3-Port Valve Failure

£9.9£99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

Replacement Honeywell SYNCHRON motors are available but are a bit more expensive. For a long time we’ve used the standard SYNCHRON motors as replacements, with very few problems. This can be difficult to feel for at first. It is most obvious when the valve has been in the Heating Only position and reverts to the mid-position. V4044C motorised valves are 3 port diverter valves. They send flow to either the hot water port or the heating port but not both, except briefly during switchover. They are 3 wire valves. Honeywell say that the manual lever located on the end of the powerhead is not a position indicator and should be used used for filling the system and for draining down only. PF Community Forums General Off-Topic Chat For Sale & Wanted Make a suggestion about the forum in general

The commonest fault with Honeywell motorised valves is motor failure. Honeywell valve motor fault? Testing a Synchron valve motor Drive spindle of a Honeywell motorised valve. It is accessed by removing the valve powerhead. Be warned, with Honeywell motorised valves made pre-1985 you have to drain down first to remove the powerhead! When the programmer and stat send a Live feed to the 2-port motorised brown wire, the motor drives the valve open to allow water to pass. When the valve is fully open, the end switch closes, allowing electrical current to pass from the grey wire to the orange wire and from there to the boiler Switched Live. Unless the boiler thermostat is already up to temperature, the boiler will now fire.The Honeywell mid-position motorised valve has three ports in a T configuration. Water enters via port AB. Water leaves by either port A or port B or by both at the same time. Port A is normally connected to the radiator circuit and Port B to the cylinder coil (to heat hot water). The circulating pump is usually connected to feed water from the boiler into port AB. On modern Honeywell valves, if the powerhead fails it can be removed from the valve body without draining down. However,be warned!With very old Honeywell motorised valves the powerhead could not be removed without draining the water first. The Honeywell V4073A 3-port valve has five wires. These are blue, green/yellow, white, grey and orange. Note that the grey and orange wires are used differently from the grey and orange wires of the 2-port valve!

The Honeywell V4073A is a spring-return valve. Port A or port B can be closed by a rubber ball, though never both at the same time. The rubber ball is moved between ports A and B by an actuator shaft or spindle which is driven by the powerhead. The inlet port AB can never be closed; the ball only moves between port A and port B.

Inside a Honeywell V4073A 3-port motorised valve showing the rubber ball which closes one or other port, never both.

Asda Great Deal

Free UK shipping. 15 day free returns.
Community Updates
*So you can easily identify outgoing links on our site, we've marked them with an "*" symbol. Links on our site are monetised, but this never affects which deals get posted. Find more info in our FAQs and About Us page.